https://www.selleckchem.com/products/bx-795.html
Development of thermally stable spray dried viral-vectored vaccine powders is dependent on the selection of a proper excipient or excipient blend for encapsulation, which can be a time and resource intensive process. In this work, a diffusion-based droplet drying model was developed to compute droplet drying time, size, and component distribution. The model predictions were validated using an acoustic levitator to dry droplets containing protein-coated or fluorescently labelled silica nanoparticles (as adenoviral vector analogues) and a