https://www.selleckchem.com/products/cpi-1205.html
Reference standards for the vitamin D metabolites 25-hydroxyvitamin D3, 25-hydroxyvitamin D2, and 3-epi-25-hydroxyvitamin D3 were evaluated using liquid chromatography (LC) with ultraviolet (UV) absorbance and mass spectrometric (MS) detection to assess purity. The chromatograms for solutions of all three 25(OH)D compounds, obtained using a pentafluorophenyl (PFP) stationary phase, revealed peaks that increased in area over time and had MS spectra that were nearly identical to the parent compound, indicating isomers had formed in solut